Sidewall Cleat conveyor belt
A. Bucket bolts pull through belt or belt tears at bolt hole:
1. Bucket bolts not tight. Inspect frequently and tighten as required.
2. Inadequate belt construction for holding bolts. Replace belt with one properly designed.
3. Obstruction in casing or insufficient clearance. Check terminal pulleys for proper alignment to insure straight-running belt. Redesign elevator if necessary.
4. Jammed boot. Install controlled feed to help eliminate jams and turbulence in boot.
5. Pulleys too small or incorrect belt splice strains bolts as belt flexes. Install larger head pulley […]